HY series

Driven fans oil coolers with AC, DC power, electric motor and hydraulic motor predisposition.

Download the catalog

The new HY series guarantees maximum installation flexibility for the user and greater compactness.
A wider range that allows a correct selection based on different application needs, also thanks to a wide range of accessories.

 

General characteristics:

  • electric blower fans
  • maximum working pressure (Ps) 16 bar
  • test pressure (Pt) 24 bar
  • maximum working temperature 120° (higher upon request).
The standard version of the HY series includes a one-pass circuit and a suction fan, other versions are available on request.
serie-hy

Product sheets

Fan unit selection:

  • AC
  • DC
  • Hydraulic motor
  • Electric motor
AC | 01A Single phase 230V - 03A Three phase 230-400V

MODELFLOW [l/min]COOLING POWER [kW]
 MinMaxMinMax
Serie 100[preview]
HY005.1-01A2,5251,22,1
HY010.1-01A105022,9
HY010.1-03A105022,9
HY016.1-01A10902,95
HY016.1-03A10902,95
HY018.1-01A201404,76,4
HY018.1-03A201404,76,4
HY024.1-01A201406,710,5
HY024.1-03A201406,710,5
HY038.1-01A201408,815,9
HY038.1-03A201408,815,9
HY057.1-01A2016010,920,3
HY057.1-03A2016010,920,3
HY090.1-01A3019015,928
HY090.1-03A3019015,928
Serie 200[preview]
HY210.1-03A3514012,918,5
HY215.1-03A3514014,119,5
HY220.1-03A4016018,927
HY225.1-03A4518027,443,7
HY230.1-03A5522034,354,5
HY232.1-03A7028039,156,2
HY235.1-03A702804055,2
ΔT in oil/T amb= 40 K
DC | 02A 12V - 04A 24V

MODELFLOW [l/min]COOLING POWER [kW]
 MinMaxMinMax
Serie 100
HY005.1-02A2,5251,22,1
HY005.1-04A2,5251,22,2
HY010.1-02A10502,23,1
HY010.1-04A10502,13,1
HY016.1-02A10902,74,5
HY016.1-04A10902,74,5
HY018.1-02A201404,97,1
HY018.1-04A2014057,3
HY024.1-02A201406,610,1
HY024.1-04A201406,610,2
HY038.1-02A201408,314,5
HY038.1-04A201408,414,6
HY057.1-02A2016011,120,8
HY057.1-04A2016010,920,3
HY090.1-02A3019014,624,5
HY090.1-04A3019014,724,9
Serie 200
HY210.1-02A3514013,219,3
HY210.1-04A351401318,9
HY215.1-02A3514014,720,8
HY215.1-04A3514014,420,2
HY220.1-02A4016018,225,2
HY220.1-04A4016017,924,6
HY225.1-02A4518023,834,7
HY225.1-04A4518024,436,4
ΔT in oil/T amb= 40 K
Suitable for hydraulic motor | 05A GR2 - 06A GR3

MODELFLOW [l/min]COOLING POWER [kW]
 MinMaxMinMax
Serie 100
HY024.1-05A2014068,7
HY038.1-05A201407,511,5
HY057.1-05A201601120,6
HY090.1-05A3019016,429,3
Serie 200
HY210.1-05A351401319
HY215.1-05A3514014,420,1
HY220.1-05A4016020,231
HY225.1-05A451802538,4
HY230.1-05A5522032,650,5
HY230.1-06A5522032,650,5
HY232.1-05A7028038,554,5
HY232.1-06A7028038,554,5
HY235.1-05A7028039,954,8
HY235.1-06A7028039,954,8
ΔT in oil/T amb= 40 K
Electric Motor | 07A B14

MODELFLOW [l/min]COOLING POWER [kW]
 MinMaxMinMax
Serie 100
HY024.1-07A201405,77,9
HY038.1-07A201407,210,7
HY057.1-07A2016010,719,6
HY090.1-07A3019015,927,9
Serie 200
HY210.1-07A3514012,718
HY215.1-07A351401418,9
HY220.1-07A4016019,829,7
HY225.1-07A4518024,536,6
HY230.1-07A5522031,548,1
HY232.1-07A7028040,259,6
HY235.1-07A7028041,860
ΔT in oil/T amb= 40 K